Attest Super Rapid Readout Biological Indicators, 50/Pkg 1492V

Attest Super Rapid Readout Biological Indicators, 50/Pkg 1492V

SKU: 3M-1492V In Stock
Regular price$332.99

Attest™ Super Rapid Biological Indicators monitor the efficacy of steam sterilization processes with quick and reliable results. The 3M™ Attest™ Super Rapid Readout Biological Indicator 1492V (brown cap, referred to hereinafter as the 1492V BI) is a self-contained biological indicator specifically designed for rapid and reliable qualification testing and routine monitoring of 270°F (132°C) and 275°F (135°C) dynamic-air-removal (pre-vacuum) steam sterilization processes when used in conjunction with the 3M™ Attest™ Auto-reader 490 (hereinafter referred to as the 490 Auto-reader). The 1492V BI is a single-use device.

 

Readout Times: 

The 1-hour super rapid readout and the optional 48-hour visual pH color change incubation times have been correlated with a 7-day incubation period (at 56+/-2°C) following the FDA’s Reduced Incubation Time protocol. Processed indicators were examined at 48 hours and 7 days for detection of a visual pH color change.

The 1-hour fluorescence change readings and the 48-hour visual pH color change readings were compared to the 7-day visual pH color change readings to determine the readout time of the indicator. 1-hour Fluorescence Change Result 1492V BIs have 1-hour reduced incubation time results that correlate to the 7-day (168 hours) visual readout result ≥ 97% of the time. 48-hour Visual pH Color Change Result 1492V BIs have 48-hour reduced incubation time results that correlate to the 7-day (168 hours) visual readout result ≥ 97% of the time. Due to the high reliability of the 1-hour fluorescent result there is no advantage to incubating 1492V BIs beyond 1 hour. 1492V BIs meet ANSI/AAMI/ISO 11138-1:2006/(R)2010, ANSI/AAMI/ISO 11138-3:2006/(R)2010 and BS EN/ISO 11138-1:2006, BS EN/ISO 11138-3:2006.

 

  • Provides BI results in 24 minutes in 3M Attest 490/490H Auto-readers with software version 4.2.7 or greater
  • Dynamic-air-removal (Pre-vacuum and SFPP): 132˚C (270˚F) 3 or 4 min. 135˚C (275˚F) 3 min.
  • Meets ISO and FDA performance requirements for biological indicators
  • Contains viable organisms that provide a direct measure of lethality
  • Puts your instrument turnaround speed into overdrive
  • Puts your instrument turnaround speed into overdrive for improved patient safety
  • *When used with 3M™ Attest™ Auto-reader 490 or the Attest™ Auto-reader 490H with software version 4.2.7 or greater.
  • Twenty-four minute readout Biological Indicator for 132°C (270°F) 3 or 4 minute and 135°C (275°F) 3 minute Dynamic-Air-Removal Steam Sterilization cycles (Brown Cap). 50 each/box.

Safety Data Sheet

Size: 50 Vials/Box
Quantity
Add to wishlist
Add to compare
Tags :

Help

If you have any questions, you are always welcome to contact us. We'll get back to you as soon as possible, withing 24 hours on weekdays.

Customer service

All questions about your order, return and delivery must be sent to our customer service team by e-mail at yourstore@yourdomain.com

Sale & Press

If you are interested in selling our products, need more information about our brand or wish to make a collaboration, please contact us at press@yourdomain.com

Description

Attest™ Super Rapid Biological Indicators monitor the efficacy of steam sterilization processes with quick and reliable results. The 3M™ Attest™ Super Rapid Readout Biological Indicator 1492V (brown cap, referred to hereinafter as the 1492V BI) is a self-contained biological indicator specifically designed for rapid and reliable qualification testing and routine monitoring of 270°F (132°C) and 275°F (135°C) dynamic-air-removal (pre-vacuum) steam sterilization processes when used in conjunction with the 3M™ Attest™ Auto-reader 490 (hereinafter referred to as the 490 Auto-reader). The 1492V BI is a single-use device.

 

Readout Times: 

The 1-hour super rapid readout and the optional 48-hour visual pH color change incubation times have been correlated with a 7-day incubation period (at 56+/-2°C) following the FDA’s Reduced Incubation Time protocol. Processed indicators were examined at 48 hours and 7 days for detection of a visual pH color change.

The 1-hour fluorescence change readings and the 48-hour visual pH color change readings were compared to the 7-day visual pH color change readings to determine the readout time of the indicator. 1-hour Fluorescence Change Result 1492V BIs have 1-hour reduced incubation time results that correlate to the 7-day (168 hours) visual readout result ≥ 97% of the time. 48-hour Visual pH Color Change Result 1492V BIs have 48-hour reduced incubation time results that correlate to the 7-day (168 hours) visual readout result ≥ 97% of the time. Due to the high reliability of the 1-hour fluorescent result there is no advantage to incubating 1492V BIs beyond 1 hour. 1492V BIs meet ANSI/AAMI/ISO 11138-1:2006/(R)2010, ANSI/AAMI/ISO 11138-3:2006/(R)2010 and BS EN/ISO 11138-1:2006, BS EN/ISO 11138-3:2006.

 

  • Provides BI results in 24 minutes in 3M Attest 490/490H Auto-readers with software version 4.2.7 or greater
  • Dynamic-air-removal (Pre-vacuum and SFPP): 132˚C (270˚F) 3 or 4 min. 135˚C (275˚F) 3 min.
  • Meets ISO and FDA performance requirements for biological indicators
  • Contains viable organisms that provide a direct measure of lethality
  • Puts your instrument turnaround speed into overdrive
  • Puts your instrument turnaround speed into overdrive for improved patient safety
  • *When used with 3M™ Attest™ Auto-reader 490 or the Attest™ Auto-reader 490H with software version 4.2.7 or greater.
  • Twenty-four minute readout Biological Indicator for 132°C (270°F) 3 or 4 minute and 135°C (275°F) 3 minute Dynamic-Air-Removal Steam Sterilization cycles (Brown Cap). 50 each/box.

Safety Data Sheet