The 3M™ Attest™ 1292 Rapid Readout Biological Indicator, identified by its distinctive brown cap, offers fast and reliable monitoring of steam sterilization cycles. Suitable for both 121 °C gravity displacement (250 °F) and 132 °C vacuum-assisted (270 °F) steam processes, this self-contained indicator delivers results in just 3 hours when used with the appropriate 3M™ Attest™ Auto-reader.
-
Accelerated Fluorescent Readout
Thanks to high enzyme sensitivity, the indicator delivers dependable results in 3 hours—enabling rapid sterilization load verification and reducing downtime. -
Dual Readout Design
Features both a fluorescent readout via the auto-reader and a visual pH-based color change (rose to brown), providing a backup confirmation mechanism. -
Robust, Self-Contained Construction
Each vial includes Geobacillus stearothermophilus spores, internal growth media, and a protective cap with a chemical indicator. This all-in-one design reduces contamination risk and simplifies handling. -
Standards-Compliant & Color-Coded
Meets global standards (ISO 11138-1:2017 and -3:2017 / ANSI/AAMI 11138) and its brown cap provides quick, visual identification in sterilization workflows. -
Compatible with Multiple Auto-Readers
Designed to work seamlessly with 3M™ Attest™ Auto-readers—290 Series, 390, and legacy 293—providing flexibility across varied clinical setups.
The 3M™ Attest™ 1292 Rapid Readout Biological Indicator, identified by its distinctive brown cap, offers fast and reliable monitoring of steam sterilization cycles. Suitable for both 121 °C gravity displacement (250 °F) and 132 °C vacuum-assisted (270 °F) steam processes, this self-contained indicator delivers results in just 3 hours when used with the appropriate 3M™ Attest™ Auto-reader.
-
Accelerated Fluorescent Readout
Thanks to high enzyme sensitivity, the indicator delivers dependable results in 3 hours—enabling rapid sterilization load verification and reducing downtime. -
Dual Readout Design
Features both a fluorescent readout via the auto-reader and a visual pH-based color change (rose to brown), providing a backup confirmation mechanism. -
Robust, Self-Contained Construction
Each vial includes Geobacillus stearothermophilus spores, internal growth media, and a protective cap with a chemical indicator. This all-in-one design reduces contamination risk and simplifies handling. -
Standards-Compliant & Color-Coded
Meets global standards (ISO 11138-1:2017 and -3:2017 / ANSI/AAMI 11138) and its brown cap provides quick, visual identification in sterilization workflows. -
Compatible with Multiple Auto-Readers
Designed to work seamlessly with 3M™ Attest™ Auto-readers—290 Series, 390, and legacy 293—providing flexibility across varied clinical setups.